Products SpringPark UI Sequences
April 13, 2023 at 2:39 AMUI sequences for SpringPark
ID | Name | Meaning | Description |
---|---|---|---|
01 |
NO MOTHER BOARD | Error sequence | - All LEDs: Group flashing x3, light time 5%, period 100ms |
03 |
HARDWARE ERROR | Error sequence for any hardware error / self test failed state | - All LEDs: Group flashing x3, light time 5%, period 100ms |
04 |
NOT GENUINE | Counterfeit detected | - All LEDs: Group flashing x3, light time 5%, period 100ms - Buzzer ON during 1s - Pause; wait during 1s - Restore earlier UI sequence |
05 |
CANCEL | Cancel all sequences | - All LEDs OFF |
06 |
STARTUP | The device is starting up | - All LEDs: Solid ON |
07 |
SHUTDOWN | The device is shutting down | - All LEDs OFF |
08 |
PLEASE WAIT | Generic wait sequence (device is busy / user action required) | - 1st LED: Blinking, isophase (light time 50%), period 200ms - 2nd LED: Switch OFF - 3rd LED: Switch OFF - 4th LED: Switch OFF |
09 |
BOOTLOADER WAITING | Error sequence | - 1st LED: Blinking, isophase (light time 50%), period 200ms - 2nd LED: Switch OFF - 3rd LED: Switch OFF - 4th LED: Blinking, isophase (light time 50%), period 200ms |
0A |
FW UPGRADING | Firmware updated in progress, DON’T SWITCH OFF / UNPOWER THE DEVICE NOW | - 1st LED: Blinking, isophase (light time 50%), period 200ms - 2nd LED: Switch OFF - 3rd LED: Switch OFF - 4th LED: Blinking, isophase (light time 50%), period 100ms |
0B |
FW UPGRADED | The firmware has been updated | - 1st LED: Blinking, isophase (light time 50%), period 200ms - 2nd LED: Switch OFF - 3rd LED: Switch OFF - 4th LED: Group flashing x2, light time 20%, period 100ms - Buzzer ON during 500ms - Pause; wait during 2s |
0C |
CONFIG CLEARED | Factory settings have been restored | - 1st LED: Blinking, isophase (light time 50%), period 200ms - 2nd LED: Switch OFF - 3rd LED: Switch OFF - 4th LED: Group flashing x4, light time 5%, period 100ms Repeat 3 times { - Buzzer ON during 20ms - Pause; wait during 200ms } |
0D |
SELF TEST | Self-test sequence | Repeat forever { - 1st LED: Blinking, isophase (light time 50%), period 200ms - 2nd LED: Switch OFF - 3rd LED: Switch OFF - 4th LED: Switch OFF - Pause; wait during 500ms - 1st LED: Solid ON - 2nd LED: Blinking, isophase (light time 50%), period 200ms - 3rd LED: Switch OFF - 4th LED: Switch OFF - Pause; wait during 500ms - 1st LED: Solid ON - 2nd LED: Solid ON - 3rd LED: Blinking, isophase (light time 50%), period 200ms - 4th LED: Switch OFF - Pause; wait during 500ms - 1st LED: Solid ON - 2nd LED: Solid ON - 3rd LED: Solid ON - 4th LED: Blinking, isophase (light time 50%), period 200ms - Pause; wait during 500ms - All LEDs: Solid ON - Pause; wait during 500ms - 1st LED: Switch OFF - 2nd LED: Solid ON - 3rd LED: Solid ON - 4th LED: Solid ON - Pause; wait during 500ms - 1st LED: Switch OFF - 2nd LED: Switch OFF - 3rd LED: Solid ON - 4th LED: Solid ON - Pause; wait during 500ms - 1st LED: Switch OFF - 2nd LED: Switch OFF - 3rd LED: Switch OFF - 4th LED: Solid ON - Pause; wait during 500ms - All LEDs: Switch OFF - Pause; wait during 500ms - Buzzer ON during 500ms } |
0E |
WINK | Wink! | Repeat 10 times { - Buzzer ON during 100ms - All LEDs: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 500ms - All LEDs OFF } - Restore earlier UI sequence |
0F |
BLACKOUT | Going to sleep mode (not shutdown) | Store current sequence - All LEDs OFF |
10 |
STARTED IDLE | Started, waiting for activation | Store current sequence - 1st LED: Flashing, light time 10%, period 4s - 2nd LED: Switch OFF - 3rd LED: Switch OFF - 4th LED: Switch OFF |
11 |
STARTED ACTIVE | Started, activated | - Buzzer ON during 10ms - Continue with sequence NFC RFID ACTIVE |
13 |
STATE SUSPEND | USB suspended | Store current sequence - Buzzer ON during 100ms - RGB LED: Solid ON - RGB LED: Fade to Black ( 000000 ), duration 100ms |
20 |
NFC RFID INACTIVE | Started, field is OFF | Store current sequence Run internal hook (may replace the default color by a configuration-defined color) - 1st LED: Flashing, light time 10%, period 500ms - 2nd LED: Switch OFF - 3rd LED: Switch OFF - 4th LED: Switch OFF |
21 |
NFC RFID ACTIVE | Started, field is ON / device is polling | Store current sequence Run internal hook (may replace the default color by a configuration-defined color) - 1st LED: Solid ON - 2nd LED: Switch OFF - 3rd LED: Switch OFF - 4th LED: Switch OFF |
22 |
NFC RFID TAG READING | A NFC or RFID tag is being read | - 1st LED: Solid ON - 2nd LED: Solid ON - 3rd LED: Switch OFF - 4th LED: Switch OFF |
23 |
NFC RFID TAG READ SUCCESS | A NFC or RFID tag has been read | - 1st LED: Solid ON - 2nd LED: Solid ON - 3rd LED: Solid ON - 4th LED: Switch OFF - Buzzer ON during 100ms - All LEDs: Solid ON - Pause; wait during 2,4s - Continue with sequence NFC RFID ACTIVE |
24 |
NFC RFID TAG READ FAILED | Reading the NFC or RFID tag has failed | - All LEDs: Switch OFF - Buzzer ON during 500ms - Pause; wait during 2s - Continue with sequence NFC RFID ACTIVE |
25 |
NFC RFID TAG READ AGAIN | Please present the same NFC or RFID tag again | - 1st LED: Blinking, isophase (light time 50%), period 100ms - 2nd LED: Switch OFF - 3rd LED: Switch OFF - 4th LED: Switch OFF - Pause; wait during 2,5s - Continue with sequence NFC RFID ACTIVE |
28 |
NFC RFID TAG INSERT | A NFC or RFID tag has been found | - 1st LED: Solid ON - 2nd LED: Solid ON - 3rd LED: Switch OFF - 4th LED: Switch OFF - Buzzer ON during 100ms - Continue with sequence NFC RFID TAG PRESENT |
29 |
NFC RFID TAG PRESENT | A NFC or RFID tag is kept present | Store current sequence - 1st LED: Solid ON - 2nd LED: Solid ON - 3rd LED: Solid ON - 4th LED: Switch OFF |
2A |
NFC RFID TAG ACTIVE | A NFC or RFID tag is present and busy | - 1st LED: Solid ON - 2nd LED: Solid ON - 3rd LED: Blinking, isophase (light time 50%), period 100ms - 4th LED: Switch OFF - Pause; wait during 100ms - Continue with sequence NFC RFID TAG PRESENT |
2B |
NFC RFID TAG ERROR | A NFC or RFID tag is present but we failed communicating with it | - 1st LED: Solid ON - 2nd LED: Solid ON - 3rd LED: Switch OFF - 4th LED: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 100ms - Continue with sequence NFC RFID ACTIVE |
2C |
NFC RFID TAG COUNTERFEIT | A NFC or RFID tag is present but we know it is not genuine | - 1st LED: Solid ON - 2nd LED: Solid ON - 3rd LED: Blinking, isophase (light time 50%), period 100ms - 4th LED: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 100ms - Continue with sequence NFC RFID ACTIVE |
30 |
PROFILE DIRECT | Starting with SpringCore Direct profile | - All LEDs: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 100ms - 1st LED: Switch OFF - 2nd LED: Blinking, isophase (light time 50%), period 100ms - 3rd LED: Switch OFF - 4th LED: Switch OFF - Pause; wait during 900ms |
32 |
PROFILE CDC | Starting with CDC (serial emulation) profile | - All LEDs: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 100ms - 1st LED: Switch OFF - 2nd LED: Switch OFF - 3rd LED: Switch OFF - 4th LED: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 900ms |
33 |
PROFILE CCID | Starting with CCID (PC/SC) profile | - All LEDs: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 100ms - 1st LED: Switch OFF - 2nd LED: Switch OFF - 3rd LED: Blinking, isophase (light time 50%), period 100ms - 4th LED: Switch OFF - Pause; wait during 900ms |
34 |
PROFILE HID | Starting with HID (keyboard emulation) profile | - All LEDs: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 100ms - 1st LED: Switch OFF - 2nd LED: Switch OFF - 3rd LED: Blinking, isophase (light time 50%), period 100ms - 4th LED: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 900ms |
3E |
PROFILE SPECIAL | Starting with another profile | - All LEDs: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 100ms - 1st LED: Switch OFF - 2nd LED: Blinking, isophase (light time 50%), period 100ms - 3rd LED: Switch OFF - 4th LED: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 900ms |
3F |
PROFILE ERROR | The profile specified in register 02C0 is not supported |
- All LEDs: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 100ms - 1st LED: Switch OFF - 2nd LED: Blinking, isophase (light time 50%), period 100ms - 3rd LED: Blinking, isophase (light time 50%), period 100ms - 4th LED: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 900ms |
40 |
PRODUCT UNKNOWN | Hardware variant not recognized | - All LEDs: Blinking, isophase (light time 50%), period 100ms - Pause; wait during 1s |
50 |
MASTERCARD PENDING | Master-card recognized, keep it steady over the antenna | - 1st LED: Blinking, isophase (light time 50%), period 200ms - 2nd LED: Blinking, isophase (light time 50%), period 200ms - 3rd LED: Blinking, isophase (light time 50%), period 200ms - 4th LED: Switch OFF Repeat forever { - Buzzer ON during 10ms - Pause; wait during 60ms } |
51 |
MASTERCARD SUCCESS | Master-card accepted and successfully processed | - All LEDs: Blinking, isophase (light time 50%), period 200ms Repeat forever { - Buzzer ON during 300ms - Pause; wait during 700ms - Buzzer ON during 50ms - Pause; wait during 200ms - Buzzer ON during 50ms - Pause; wait during 200ms } |
52 |
MASTERCARD FAILED | Master-card rejected, or removed during processing | - 1st LED: Blinking, isophase (light time 50%), period 200ms - 2nd LED: Blinking, isophase (light time 50%), period 200ms - 3rd LED: Switch OFF - 4th LED: Blinking, isophase (light time 50%), period 200ms - Buzzer ON during 1s - Pause; wait during 2s - Continue with sequence NFC RFID ACTIVE |
54 |
COLORADO PENDING | Colorado App. or Tag. recognized, keep it steady over the antenna | - 1st LED: Blinking, isophase (light time 50%), period 200ms - 2nd LED: Blinking, isophase (light time 50%), period 200ms - 3rd LED: Blinking, isophase (light time 50%), period 50ms - 4th LED: Switch OFF Repeat forever { - Buzzer ON during 20ms - Pause; wait during 70ms } |
55 |
COLORADO SUCCESS | Data have been transmitted to Colorado App. or Tag. | - All LEDs: Blinking, isophase (light time 50%), period 200ms - Buzzer ON during 300ms - Pause; wait during 700ms - Continue with sequence NFC RFID ACTIVE |
56 |
COLORADO FAILED | Failed to transmit data to Colorado App. or Tag. | - 1st LED: Blinking, isophase (light time 50%), period 200ms - 2nd LED: Blinking, isophase (light time 50%), period 200ms - 3rd LED: Switch OFF - 4th LED: Blinking, isophase (light time 50%), period 50ms - Buzzer ON during 700ms - Pause; wait during 300ms - Continue with sequence NFC RFID ACTIVE |
60 |
ACCESS GRANTED | Tag or Token accepted, door is opening | - All LEDs: Solid ON - Buzzer ON during 100ms - Pause; wait during 2,5s - Continue with sequence NFC RFID ACTIVE |
61 |
ACCESS DENIED | Tag or Token denied | - All LEDs: Switch OFF - Buzzer ON during 600ms - Pause; wait during 1s - Continue with sequence NFC RFID ACTIVE |
80 |
NETWORK NOT LINKED | Ethernet not connected | - 1st LED: Switch OFF - 2nd LED: Switch OFF - 3rd LED: Blinking, isophase (light time 50%), period 100ms - 4th LED: Blinking, isophase (light time 50%), period 100ms |
81 |
NETWORK WAITING | Ethernet connected, waiting… | - 1st LED: Switch OFF - 2nd LED: Switch OFF - 3rd LED: Blinking, isophase (light time 50%), period 100ms - 4th LED: Flashing, light time 10%, period 1s |
82 |
NETWORK WAITING FOR CLIENT | Not connected, waiting for client application | - Buzzer ON during 20ms - 1st LED: Switch OFF - 2nd LED: Switch OFF - 3rd LED: Blinking, isophase (light time 50%), period 100ms - 4th LED: Group flashing x2, light time 10%, period 1s |
83 |
NETWORK WAITING FOR SERVER | Not connected to remote server service | - 1st LED: Switch OFF - 2nd LED: Switch OFF - 3rd LED: Blinking, isophase (light time 50%), period 100ms - 4th LED: Group flashing x3, light time 10%, period 1s |
F0 |
SHORT BEEP | Short beep | - Buzzer ON during 50ms |
Version of UI sequences: 01