Host Protocols Direct Protocol CONTROL class Actions SHUTDOWN
April 13, 2023 at 2:39 AMSHUTDOWN
Role
Ask the device to enter full power-down mode.
Warning
Not all hardware support a full power-down mode. For devices without such capabilities, this instruction is equivalent to a soft reset.
Access condition
Depending on the configuration-defined access conditions and on the type of host interface (Local / Remote), this instruction may either be freely usable or restricted to authenticated communications.
Command
Field | Value |
---|---|
CLA | 58 (CONTROL) |
INS | AF |
Data | 2 bytes, value=DEAD |
Response
None