SHUTDOWN

Role

Ask the device to enter full power-down mode.

Warning

Not all hardware support a full power-down mode. For devices without such capabilities, this instruction is equivalent to a soft reset.

Access condition

Depending on the configuration-defined access conditions and on the type of host interface (Local / Remote), this instruction may either be freely usable or restricted to authenticated communications.

Command

Field Value
CLA 58 (CONTROL)
INS AF
Data 2 bytes, value=DEAD

Response