Smart Reader features

Address : 02A0 (bank 2, register A0)

Size : 5 bytes

Default : 0001000100

Description

Key settings for Smart Reader operation

Content

Byte 0 : Options

Bit    Role Values
3-2 Anti-collision 00 : The Reader tries to enumerate all the Tags that are present
01 : The Reader stops the enumeration after having read a first Tag
03 : The Reader does not read when more than one Tag is present
1 Insert / Remove 0 : The Smart Reader sends the Tag read event only
1 : The Smart Reader sends the Tag inserted event when the tag arrives, and the Tag removed event when it has leaved
0 Auto start 0 : Smart Reader operation must be started explicitly
1 : Smart Reader operation must be started implicitly when the device is connected

Byte 1 : Output format over serial

Bit    Role Values
7-2 RFU
1-0 output_format 0 : TLV
1 : SCRDR
2 : JSON
3 : MK1

Byte 2 : Output format over bluetooth

Bit    Role Values
7-2 RFU
1-0 output_format 0 : TLV
1 : SCRDR
2 : JSON
3 : MK1

Byte 3 : Output format over network

Bit    Role Values
7-2 RFU
1-0 output_format 0 : TLV
1 : SCRDR
2 : JSON
3 : MK1

Byte 4 : Output format over usb

Bit    Role Values
7-2 RFU
1-0 output_format 0 : TLV
1 : SCRDR
2 : JSON
3 : MK1