PCSC Operation APDU Interpreter Vendor instructions SLOT CONTROL
September 8, 2025 at 7:22 AMSLOT CONTROL instruction
Use this command to finely control the behaviour of the current PC/SC slot.
Command format
| Field | Value | Remark |
|---|---|---|
| CLA | FF |
|
| INS | FB |
|
| P1 | Sub command selection | List of sub commands depend on slot type (CL or CT) |
| P2 | Sub command selection | List of sub commands depend on slot type (CL or CT) |
| Lc | Depend on the sub command | |
| DataIn | Depend on the sub command | |
| Le | 00 |
Interface-specific implementation
The actual implementation depends on the current slot. See
- SLOT_CONTROL_CL for the Contactless (NFC / RFID HF) slot
- SLOT_CONTROL_CT for one of the Contact (ID-1 or ID-000 SIM/SAM) slot